Dsc 4 Wire Smoke Detector Wiring Diagram

Multiple smokes can be wired in parallel to the same zone or each one can be wired to separate zones or.
Dsc 4 wire smoke detector wiring diagram. Connecting a 4 wire smoke detector to a wired alarm system is a slightly more complicated process than setting up most other hardwired zones. Smoke detectors and alarms help save lives and reduce structural destruction. This is usually referred to as a daisy chain and works best for ranch style homes. Verify the siren activates and the panel reports the two wire.
Because 4 wire smoke detectors have separate power and initiating in addition to wiring to the pgm they can be wired to any regular hardwired zone. Prm 2w is for use with fsa 210 series 2 wire smoke detectors with integral horns. They must be connected to a zone input. Smoke alarms provide the earliest warning of both fire and smoke.
To reset two smoke detectors press 7 2 or the reset function key. Begin pulling from the main alarm panel location past each smoke detector along the way until the last smoke is reached. This is the basic fire alarm system used in household wiring. Relay heat detector.
4 wire photoelectric smoke detector w integral sounder aux. Do not connect heat detectors to pgm2. Dsc digital security controls is a world leader in electronic security. In this video joe from alarm grid helps you determine whether you should use 2 wire or 4 wire smoke detectors with your hardwired security panel.
How do i program for a 4 wire smoke detector on a dsc 1616 1832 or 1864 system. Running 4 wire smoke detectors. In a typical home fire occupants have just minutes to escape. Studies show that smoke alarms save more lives than any other fire prevention measure.
Create an alarm on a two wire smoke detector. 4 wire photoelectric smoke detector w integral sounder heat detector. 4 wire smoke detectors can be pulled in a single run looping to each unit just like 2 wire smokes. Connection of the module to the control panel is a typical 4 wire type where a reset.
In our basic wiring diagram a single or multiple heat and smoke detectors are installed in the home by connecting the live line or hot neutral ground and an interconnected wire to the alarm. This module includes a class b style b 2 wire smoke detector zone which provides an inter face for control panels that do not have a compatible 2 wire smoke detector zone. A smoke or heat detector can be installed to the existing or new home wiring. The panel will remove power from pgm2 for five 5 seconds.
The setup will also require an end of line resistor and a relay module.