Ada Toilet Stall Requirements

All standard stalls must be at least 60 inches wide.
Ada toilet stall requirements. Grab bars in toilet stall requirements. Medical care and long term care facilities 223 1 805 4. More or less than that makes maneuvering difficult. Standard toilet stalls with a minimum depth of 56 in 1420 mm see figure here under shall have wall mounted water closets.
Water closets in accessible stalls shall comply with 4 16. Another grab bar 42 length is also used at 33 36 from the floor off the wall on the side. The size and arrangement of the standard toilet stall shall comply with figure here under standard stall. In the few places where requirements between the two differ the requirements of 28 cfr 35 151 prevail.
In a public bathroom that has stalls at least one must be a standard ada stall. Clear floor spaces must meet requirements for ground and floor surfaces including criteria for firmness stability and slip resistance. The source for the information below is the 2010 ada standards for accessible design. Accessible toilet stalls shall be on an accessible route and shall meet the requirements of 4 17 2 through 4 17 6.
And the 2004 adaag at 36 cfr part 1191 appendices b and d. Toilet flush levers are also supposed to be installed on the open side of the stall so that the user doesn t have to reach over the toilet meihls adds. Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum from the rear wall and extending 54 inches 1370 mm minimum from the rear wall. The ada standards require that unisex toilet rooms where provided have privacy latches and contain at most one lavatory one water closet and one urinal or a second water closet 213 2 1.
State and local government facilities must follow the requirements of the 2010 standards including both the title ii regulations at 28 cfr 35 151. They must be free of level changes and not slope more than 1 48. The grab bars are located off the back wall 33 36 from the floor and are 36 width. The requirements of the actual toilet grab bars and toilet paper dispenser remain essentially the same.
The minimum size 30 by 48 applies whether the space is positioned for forward or side approaches. In either alternate stall if a wall mounted water closet is used the depth of the stall is required to be a minimum of 66 inches 1675 mm. If a floor mounted water closet is used the depth of the stall is required to be a minimum of 69 inches 1745 mm. For single handicapped restrooms there must be a 60 diameter for a wheel chair in the room.
Toilets must be located within 16 18 inches from the centerline of the wall meihls says. Toilet stalls used primarily by children ages 12 and younger shall be permitted to comply with 4 17 7. However the enclosure walls must meet certain dimensional requirements.