Ada Toilet Room Grab Bars

On september 15 2010.
Ada toilet room grab bars. Grab bars in toilet stall requirements. The rear grab bar can be split or shifted to the open side to accommodate the required location of the flush control valves. Mechanical rooms boiler rooms supply storage rooms employee lounges or locker rooms janitorial closets entrances and corridors are not areas. Grab bars enlarging toilet stalls insulating pipes or installing accessible.
Ada figure 609 3 dimensions for rear grab bar installation. Grab bars for water closets not located in stalls shall comply with 4 26 and fig. Toilet paper dispensers 604 7. Grab bars in toilet stall requirements.
The bar must be 1 1 4 to 1 1 2 inches in diameter. The department of justice published revised regulations for titles ii and iii of the americans with disabilities act of 1990 ada in the federal register on september 15 2010. The source for the information below is the 2010 ada standards for accessible design. The ada standards require horizontal grab bars on the rear wall and side wall of the water closet but it does not specify a vertical grab bar.
Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum from the rear wall and extending 54 inches 1370 mm minimum from the rear wall. Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum from the rear wall and extending 54 inches 1370 mm minimum from the rear wall. But i would strongly recommend to take into consideration the height and physical capabilities of the person you are installing these grab bars for. Of the americans with disabilities act of 1990 ada in the.
See also ada requirements for seats. The grab bar behind the water closet shall be 36 in 915 mm minimum. Figure 29 grab bars at water closets. These regulations adopted revised enforceable accessibility standards called the 2010 ada standards for accessible design 2010 standards or standards.
Typically grab bars in the shower should be installed 33 to 36 inches from the floor of the bathroom this is according to ada americans with disabilities act standards. However you will often see them while in a toilet room or in the accessible stall. Rear wall grab bars shall be 36 915 mm long and mounted so 24 610 mm are to the transfer side of the toilet and the other 12 305 mm to the wall side. Figure 29b grab bars at water closets side wall.
Grab bars must be installed between 34 and 38 inches above the floor and there must be a separation between the grab bar and the wall surface of at least 1 1 2 inches. An ada compliant grab bar handrail must be fully anchored and have a smooth surface that can be easily grabbed.