Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum.
Ada toilet grab bars location. Ada grab bar requirements ada grab bar requirements for shower stalls bath tubs and toilet stalls consult manufacturer s installation instructions for proper installation of specific product. The source for the information below is the 2010 ada standards for accessible design. Grab bars complying with the length and positioning shown in figures here under shall be provided. Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum from the rear wall and extending 54 inches 1370 mm minimum from the rear wall.
If the toilet is not in a stall the rear wall grab bar must be at least 36 long with the end closer to the side wall mounted at least 12 from the centerline of the toilet and extend at least 24 on the transfer side. An ada compliant grab bar handrail must be fully anchored and have a smooth surface that can be easily grabbed. Grab bars in toilet stall requirements. Ada compliant grab bars must be mounted 33 36 above the floor.
Reach height and the 12 min. If the grab bar is 36 high a non recessed toilet paper dispenser located above the bar must have an outlet at exactly 48 high to accommodate both the max. Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum from the rear wall and extending 54 inches 1370 mm minimum from the rear wall. Grab bars in toilet stall requirements.
Keep in mind that the measurements should be taken from the top edge of the grab bar and to the centerline of the mounting flange. See also ada requirements for seats. Grab bars in toilet stall requirements. Example single user toilet room.
Clearance above the grab bar. But i would strongly recommend to take into consideration the height and physical capabilities of the person you are installing these grab bars for. Grab bars must be installed between 34 and 38 inches above the floor and there must be a separation between the grab bar and the wall surface of at least 1 1 2 inches. The bar must be 1 1 4 to 1 1 2 inches in diameter.
Toilet paper dispensers shall be below the grab bar and at least 19 inches 485 mm above the floor and no farther than 36 inches 915 mm from the rear wall measured to the far side of the dispensers. Typically grab bars in the shower should be installed 33 to 36 inches from the floor of the bathroom this is according to ada americans with disabilities act standards.