6 Gauge Wire Diameter In Inches

American wire gauge awg also known as the brown sharpe wire gauge is a logarithmic stepped standardized wire gauge system used since 1857 predominantly in north america for the diameters of round solid nonferrous electrically conducting wire.
6 gauge wire diameter in inches. The n gauge wire diameter d n in millimeters mm is equal to 0 127mm times 92 raised to the power of 36 minus gauge number n divided by 39. Conveniently determine the diameter in inches or millimeters of wire gauges from 10 to 38 gauge. The n gauge wire diameter d n in millimeters mm is equal to 0 127mm times 92 raised to the power of 36 minus gauge number n divided by 39. Wire gauge calculations wire diameter calculations.
Diameter in 005 92 36 awg 39. Dimensions of the wires are given in astm standard b 258. In the metric gauge scale the gauge is 10 times the diameter in millimeters so a 50 gauge metric wire would be 5 mm in diameter. Awg general rules of thumb for every 6 gauge decrease the wire diameter doubles and for every 3 gauge decrease the cross sectional area doubles.
Diameter mm 127 92 36 awg 39. The n gauge wire diameter d n in inches in is equal to 0 005in times 92 raised to the power of 36 minus gauge number n divided by 39. First find the exponent in the equation by subtracting the wire gauge from 36 then dividing by 39. Wire gauge refers the physical size of the wire rated with a numerical designation that runs opposite to the diameter of the conductors in other words the smaller the wire gauge number the larger the wire diameter.
The tables below are intended to be a general guide for wire size and amp ratings. Common sizes include 14 12 10 8 6 and 2 gauge wire. D n mm 0 127 mm 92 36. Note that in awg the diameter goes up as the gauge goes down but for metric gauges it is the opposite.
The size of the wire dictates how much current can safely pass. Steps to find the diameter. American wire gauge awg sizes and properties chart table table 1. The formula to find the diameter of the wire in inches is.
The cross sectional area of each gauge is an important factor for determining its. The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 volts 60 c through 90 c 140 f through 194 f not more than three current carrying conductors in raceway cable or earth directly buried based on ambient air temperature of 30 c 86 f. The formula to find the diameter of the wire in millimeters is. 60 c 140 f 75 c 167 f awg mm copper.
Note w m wire gauge us steel wire gauge and music wire gauge are different systems.